Product Description

Bio Safety Cabinets

The term biological safety cabinet is used to describe a variety of containment devices equipped with HEPA filters, which are designed to provide personnel protection or both personnel and product protection from the hazards of handling infectious materials. The cabinets are defined by class and again by type based on their construction, airflow velocities and patterns, and their exhaust system.

The term biological safety cabinet is used to describe a variety of containment devices equipped with HEPA filters, which are designed to provide personnel protection or both personnel and product protection from the hazards of handling infectious materials. The cabinets are defined by class and again by type based on their construction, airflow velocities and patterns, and their exhaust system.

The biological safety cabinet class I provides personnel and environmental protection, but no product protection. It has a limited fixed work access opening and the exhaust air is HEPA filtered, to protect the environment. The biosafety cabinet class I is designed for general microbial research with low-and moderate-risk agents.

Class IIA Biohazard Safety Cabinets provide personnel, product, and environment protection. Class II Cabinets differ in the proportion as 70% air is re-circulated within the cabinet through high efficiency particulate air (HEPA) filtration.

The biological safety cabinet class III is designed for work with bio safety level 4 microbiological agents, and provides maximum protection to the environment and the worker. It is a gas-tight enclosure with a non-opening, completely sealed, viewing window. Access to the interior of the cabinet is through a double-door pass-through interchange box that can be decontaminated between uses.

Nowhere is comfort and safety more essential than when working with hazardous materials in a biological safety cabinet. Operating in cramped conditions can make even the simplest procedure not just difficult and time-consuming – but often hazardous. Ergonomically advanced design and sophisticated controls provided in NIKHTISH bio safety cabinets give maximum operator comfort and safety.

Advantages:

  •   Safe to use
  •   Easy to use
  •   Less maintenance
  •   Comfortable
  •   Built in protection

Application:

  •   Electronic and Pharmaceutical Industries
  •   Research Centers
  •   Processing Area

  • Ambient air is pulled through the perforations located towards the work zone front to prevent contamination of the work surface and product. The inflow does not mix with the clean air within the cabinet work zone. Inflow air travels through a return path toward the air plenum at the top of the cabinet.
  • The uniform, non-turbulent air stream avoids cross contamination within and throughout the work area.
  • The down flow air stream splits with a portion moving towards the front air grille, and the remainder moving to the rear air grille. A small portion of the filtered down flow enters the intake perforations at the side capture zones at a higher velocity.
  • A combination of inflow and down flow air streams forms an air barrier that prevents contaminated room air from entering the work zone, and prevents work surface emissions from escaping the work zone.
  • Air returns to the common air plenum where @ 32% exhaust and @ 68% recirculation process is continued.

Technical Specifications :

 

Specification

Model

NE-BSF-IIA- 1210

NE-BSF-IIA-1820

NE-BSF-IIA-885

Dimension of work area

Width

1210

1820

885

Height

600

600

600

Depth

650

650

650

Overall size

Width

1410

2020

1025


Height

1990

1990

1990


Depth

900

900

900

Net weight kg

375

565

300

Cleanliness class hazardous class

100 (as per U.S.fed.std.209e) CLASS- II, Type- A – as per NSF No. 49

Efficiency

Supply air Exhaust air

HEPA 99.97 % Down to 0.3 μ

Air velocity m/s

Down flow air velocity at HEPA grill

0.45+/-0.1

For clean filter condition

Inflow air at front access opening of 150 mm

0.45+/-0.1

Air volume -

Supply – M3/Hr

1050

1575

790

Exhaust – M3/Hr

260

390

200

Power supply

230 V AC .lph, 50 Hz, Earthing

Power consumption watt (approx.)

Blower

370

555

280

Lighting

260

390

200

Construction

Main Body

Material: M.S. CRCA Surface Treatment: Powder Coating

Front Shutter

Sliding shutter with Aluminium extrusion frame & 5mm thick tempered glass with counter weight load

Table top

S.S. 304 non-glare finish with perforation at front & rear

Optional items

  • Material of construction: S.S 304
  • Surface: hand buffed to matt finish
  • Virus burner with on/off switch
  • 16/6-amp aux socket
  • Audio-video alarm for excessive front shutter opening
  • PVC ducting
  • Gas cock
  • Speed regulator for blower



NIKHTISH ENTERPRISES

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



NIKHTISH ENTERPRISES
S.No. 78/1/1, Shivkamal Industrial Estate, Behind Hindustan Bakery, Shivane, Pune - 411023, Maharashtra, India
Phone :+917210115917
Mr. Nikhil Vikas Topkar (Partner)
Mobile :+917210115917

Product Showcase
Send SMS Send Inquiry